69kV 33kV 10MVA 20MVA 30MVA ONAN Copper Oil Immersed Power Transformer

69kV 33kV 10MVA 20MVA 30MVA ONAN Copper Oil Immersed Power Transformer for Substation Step Down

Send an Inquiry
Cast Resin Dry Type Three Phase Power Distribution Transformer

Listed 11kv 13.2kv 0.4kv 1250kva 3150kva 4500kva Cast Resin Dry Type Three Phase Power Distribution Transformer

Send an Inquiry
High Quality Dry Type Isolation Transformer 3 Phase Epoxy Resin Cast CE

50kva 250kva 400kva 500kva 630kva 380v 415v 480v High Quality Dry Type Isolation Transformer 3 Phase Epoxy Resin Cast CE

Send an Inquiry
Low Loss SCB Series Epoxy Resin Cast Dry Type Transformer

Low Loss SCB Series 315kva 10kv Epoxy Resin Cast Dry Type 3 Phase Step Down Distribution Transformer

Send an Inquiry
400kva 15KV 0.4KV Step Down Transformer 3 Phase Cast Resin

400kva 15KV 0.4KV Step Down Transformer 3 Phase Cast Resin Dry Type for Industrial Power Supply & Data Centers

Send an Inquiry
IEC Standard 20KV 0.4KV Three Phase Cast Resin Dry Type Transformer

High Efficiency IEC Standard 20KV 0.4KV 30KVA Three Phase Cast Resin Dry Type Power Distribution Step Down Transformer

Send an Inquiry
3 Phase Dry Type Isolation Transformer Low Voltage

3 Phase Dry Type Isolation Transformer 100kva 400kva Low Voltage for Industrial Equipment Medical Grade

Send an Inquiry
High Quality Dry Type AC Isolation Transformer

High Quality Dry Type 220v 380v Transformer 50kva 25kva 15kva 3 Phase AC Isolation Transformer Power Transformer

Send an Inquiry
103,500+ Sq. Ft. Plant Infrastructure
3500 kVA Max Step-Up Unit Class
33 kV TEİAŞ System Voltage Level
3,000+ Global Field Deployments

Solar Inverter Duty Transformer Manufacturing for the Turkish PV Sector

Turkey’s energy landscape is undergoing a massive transformation driven by ambitious solar power deployment goals (YEKA GES projects), aggressive rooftop solar installations in industrial zones (OSB - Organize Sanayi Bölgeleri), and utility-scale solar farms across Central Anatolia, the Aegean region, and Southeastern Turkey. Central to this infrastructure is the Solar Inverter Duty Transformer, a critical electromagnetic interface that bridges low-voltage solar inverter outputs with Turkey's 11kV, 22kV, and 33kV distribution networks operated by regional DISCOs (EDAŞ) and high-voltage transmission grids under TEİAŞ (Türkiye Elektrik İletim A.Ş.).

"Unlike standard distribution transformers, solar inverter duty step-up units operate under continuous DC bias offsets, high harmonic distortion levels, severe thermal cycling, and rapid solar irradiance fluctuations unique to Mediterranean and Anatolian regional weather profiles."

As a leading international factory and exporter, our engineering ecosystem designs specialized multi-winding (split-LV) inverter duty transformers that comply directly with IEC 60076-16 (Transformers for Wind Turbine and Solar PV Application), IEC 60076 series, and local TEİAŞ Grid Code Regulations. By integrating high-grade Cold Rolled Grain Oriented (CRGO) silicon steel cores, foil-winding copper/aluminum technology, and electrostatic grounded shields between primary and secondary windings, our transformers deliver maximum efficiency and longevity under intense operational stress.

Engineering Innovations for Utility-Scale Solar PV

Specific design choices that set solar inverter duty step-up transformers apart from standard utility distribution units.

Multi-Winding Split-LV Design

Engineered with double, triple, or quadruple low-voltage (LV) windings on a single magnetic core. This allows multiple central or string inverters to connect to a single transformer substation, reducing balance-of-plant (BOP) costs while maintaining galvanic isolation between inverter channels.

Electrostatic Shielding

High-conductivity copper electrostatic screens placed between the high-voltage (HV) and low-voltage (LV) windings eliminate high-frequency capacitive cross-coupling. This shields solar inverters from grid voltage surges and prevents high-frequency switching harmonics from penetrating the TEİAŞ grid.

Harmonic & K-Factor Rating

Solar inverters generate non-sinusoidal current waveforms enriched with high-order harmonics (5th, 7th, 11th, 13th). Our transformers are custom-rated for K-Factor (K-9, K-13, up to K-20), utilizing foil winding to suppress eddy current losses and prevent internal hot-spot degradation.

Localized Technical Scenarios Across Turkey's Solar Ecosystem

Exporting electrical equipment to Turkey requires precise technical alignment with regional climatic variations and regulatory frameworks enforced by Turkish authorities, including TSE (Türk Standardları Enstitüsü) alignment and DISCO (EDAŞ) regional requirements such as Meram EDAŞ, Toroslar EDAŞ, and GDZ Elektrik.

1. High-Ambient & High-Altitude Operations (Central Anatolia)

Solar installations in regions like Konya (Karapınar solar basin), Niğde, and Kayseri experience intense summer heat combined with high altitudes (exceeding 1000m above sea level). High altitude reduces air density and thermal dissipation efficiency. Our transformers incorporate custom-engineered cooling radiators (ONAN/ONAF) and upgraded temperature rise design limits (50°C Oil / 55°C Winding) to guarantee uninterrupted output at peak solar noon.

2. Industrial Rooftop PV Systems (Marmara & Aegean OSBs)

Factories in Bursa, Kocaeli, Izmir, and Manisa are rapidly installing self-consumption rooftop PV projects. Because of space constraints and strict fire safety codes inside industrial zones, our Cast Resin Dry-Type Transformers (SCB Series up to 33kV) with F1 fire-proof rating and E2 environmental resistance offer a safe, oil-free step-up solution with zero risk of fluid leakage.

3. Coastal & Corrosive Atmosphere Adaptation (Antalya & Mediterranean)

Coastal solar installations face high humidity and airborne salinity. Our oil-immersed transformers feature shot-blasted steel tanks coated with multi-layer C4-M/C5-M maritime-grade epoxy polyurethane paint systems, stainless steel hardware, and sealed conservator systems to prevent oil oxidation and external rust.

Technical Specification Matrix: Standard Power vs. Solar Inverter Duty Transformers

The table below highlights the crucial engineering parameters required when procuring step-up units for Turkish solar energy projects.

Parameter / Feature Standard Distribution Transformer Synergy Solar Inverter Duty Transformer TEİAŞ / IEC Requirement Benefit
Primary Application Grid step-down for linear loads Solar PV Inverter grid step-up Optimized for bi-directional energy flow
Harmonic Capability Standard sinusoidal (K-1) K-Factor Rated (K-9 to K-20) Handles THD without excessive thermal degradation
Winding Configuration 2 Windings (HV/LV) Multi-Winding Split (Dual/Triple LV) Connects multiple central inverters into one unit
Inter-winding Shielding Optional or none Electrostatic Copper Shielding Mitigates high-frequency noise and inverter surge
DC Bias Withstand Not rated for DC components Enhanced Core Saturation Margin Prevents core saturation caused by inverter DC injection
Winding Technology Conventional round wire Advanced Continuous Copper/Alu Foil Uniform short-circuit stress distribution
Cooling Options Standard ONAN ONAN / ONAF / Ester-Oil Fluid Reliable thermal management at +45°C ambient

Factory Capability & Manufacturing Excellence

Operating from our modern, ISO-certified 103,500+ sq. ft. manufacturing facility in Rajkot, Gujarat, India, Synergy Transformers Pvt. Ltd. (founded 2004) has established itself as an authoritative global partner for utility companies, renewable EPC contractors, and industrial groups worldwide.

Foil Winding Supremacy

Utilizing automated foil winding machinery, our coils eliminate axial short-circuit forces associated with conventional wire windings. This structural benefit provides exceptional mechanical integrity during sudden grid-side faults.

In-House Testing Bay

Every single unit undergoes rigorous routine testing to IEC 60076 standards before dispatch, including winding resistance, voltage ratio, phase displacement, no-load loss, load loss, and separate-source power frequency withstand tests.

Export & Logistics Handling

We provide full seaworthy packaging, containerized or breakbulk shipping options directly to Turkish ports such as Ambarlı, Izmir, Mersin, and Gebze, backed by complete technical documentation dossiers, type test reports, and GA drawings.

Frequently Asked Questions by Turkish EPCs & Importers

Clear, direct answers regarding technical compliance, customs documentation, and customization for Turkish energy projects.

Do your transformers meet the TEİAŞ grid code for solar plant step-up substations?

Yes. Our solar inverter duty transformers are engineered specifically to comply with TEİAŞ transmission and grid connection regulations. We customize voltage vector groups (such as Dy11, Dy11y11, or YNd11), short-circuit impedance values (typically 6% to 10%), and insulation levels (up to 36kV class) to meet grid tie-in specs.

How do you handle customs clearance and ATR / EUR.1 certification for export to Turkey?

Our global logistics team manages complete export documentation required for Turkish customs. We supply Commercial Invoices, Packing Lists, Certificates of Origin, Bill of Lading, Test Reports, and CE declarations. We work closely with Turkish freight forwarders to ensure seamless delivery to site.

Why is foil winding superior for solar inverter applications compared to round wire winding?

Solar inverters subject transformers to high eddy-current losses due to high-frequency harmonics. Foil winding features a full-width continuous conductor layer that dramatically reduces eddy current losses, eliminates axial mechanical displacement under short-circuit conditions, and lowers hot-spot temperatures, extending insulation life by up to 30%.

What ambient temperature limits are used for transformers destined for Central/Southern Turkey?

Standard transformers are rated for 40°C ambient temperature. However, for Turkish solar farms located in high-heat zones like Konya, Şanlıurfa, or Antalya, we design our cooling systems based on a 45°C or 50°C peak ambient rating, utilizing optimized oil channels and extra radiator panels to prevent derating.

Can Turkish buyers perform factory witness testing (FAT)?

Absolutely. We welcome Turkish EPC engineers, utility consultants, or third-party inspection agencies (such as SGS, Bureau Veritas, or TÜV) to witness routine and type testing at our factory test bay prior to shipment. Remote live-video witness testing is also fully supported.